Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	70
Date	08/12/14
Start Time	11:52:15
Diameter Midpoint
 10.9	21115
 11.3	318614
 11.8	642743
 12.2	496062
 12.6	454565
 13.1	419933
 13.6	387473
 14.1	348432
 14.6	306636
 15.1	265684
 15.7	226268
 16.3	187457
 16.8	152332
 17.5	120255
 18.1	91587.6
 18.8	70393.7
 19.5	54188.3
 20.2	43011.4
 20.9	34600.9
 21.7	28295.4
 22.5	24393.4
 23.3	22151.8
 24.1	20707.4
 25.0	19559.2
 25.9	18124.7
 26.9	18065.8
 27.9	18531.3
 28.9	19568
 30.0	20954.1
 31.1	22386.6
 32.2	24776.8
 33.4	28750.1
 34.6	31756.2
 35.9	33888.3
 37.2	35017.4
 38.5	35134.4
 40.0	33875.4
 41.4	32733.3
 42.9	30417.7
 44.5	28428.1
 46.1	25726.3
 47.8	22502.4
 49.6	20431.2
 51.4	17854.1
 53.3	16205.6
 55.2	14663.4
 57.3	13595.6
 59.4	13089.7
 61.5	12052.2
 63.8	11323.2
 66.1	10796.2
 68.5	9831.68
 71.0	8369.31
 73.7	6786.53
 76.4	5541.42
 79.1	4316.35
 82.0	3200.2
 85.1	2314.89
 88.2	1866.41
 91.4	1301.9
 94.7	979.251
 98.2	760.996
101.8	594.826
105.5	443.938
109.4	318.001
113.4	270.343
117.6	196.417
121.9	181.643
126.3	116.297
131.0	99.2063
135.8	91.8039
140.7	62.901
145.9	81.3939
151.2	54.5664
156.8	43.9356
162.5	51.1969
168.5	46.1938
174.7	42.8654
181.1	31.2901
187.7	31.9611
194.6	32.2503
201.7	24.2483
209.1	35.2298
216.7	40.8923
224.7	18.2079
232.9	17.5905
241.4	13.4384
250.3	14.7559
259.5	12.4541
269.0	17.1394
278.8	17.8123
289.0	16.8031
299.6	4.04151
310.6	6.12555
322.0	10.3771
333.8	11.1829
346.0	10.0295
358.7	9.22482
371.8	3.86675
385.4	6.61491
399.5	9.23933
414.2	4.63798
429.4	2.36349
445.1	0
461.4	1.49855
478.3	0.962
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.1406
High Voltage	9874.34
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	13.7846
Mean(nm)	17.6776
Geo. Mean(nm)	15.8529
Mode(nm)	11.7574
Geo. Std. Dev.	1.50015
Total Concentration(#/cm)	5.41548e+006
Comment	